Error code and solution of Daguang induction cap sealer
Water cooled induction cap sealer
Error Code |
Cause |
Solution |
E01 |
Input voltage is lower than 175V |
Ensure that the machine is used at rated voltage(AC 220 V) |
E02 |
There is air in the water pump Water flow less than 1.5L per minute The water in the water tank is less than the lowest value Water temperature is too high(higher than 60 ℃) Water flow sensor failure |
Drain the pump air. Add water to above the water level. Drain the hot water of the water tank, and then add cold water. Clean the water flow sensor or replace a new one |
E12 |
Water flow less than 1.5L when turned on for the first time |
Drain the pump air. Add water to above the water level. |
E03 |
The power tube overheating |
Improve the main unit ventilation environment |
E04 | Overload |
Appropriate increase the distance of the heating sensor from the bottle |
E05 |
Heating sensor disengagement |
Check the heating sensor connection |
E06 |
Overcurrent or other faults Heating sensor faults |
Please refer to items 4 and 6 above Repair the heating sensor |
Air cooled induction cap sealer
Error Code |
Cause |
Solution |
E01 |
Input voltage is lower than 175V |
Ensure that the machine is used at rated voltage(AC 220 V) |
E02 |
The control line of the Heating sensor disengagement |
Check the heating sensor connection |
E03 |
The power tube overheating |
Improve the main unit ventilation environment |
E04 | Overload |
Appropriate increase the distance of the heating sensor from the bottle |
E05 |
Heating sensor disengagement |
Check the heating sensor connection |
E06 |
Overcurrent or other faults |
Please refer to items 4 and 6 above |