+86 18177333457 | [email protected]
Home/News/Company news/Error code and solution of Daguang induction cap sealer

Error code and solution of Daguang induction cap sealer

Error code and solution of Daguang induction cap sealer

Water cooled induction cap sealer

Error Code Cause
Solution
E01

Input voltage is lower than 175V

Ensure that the machine is used at rated voltage(AC 220 V)

E02

There is air in the water pump

Water flow  less than 1.5L per minute

The water in the water tank is less than the lowest value

Water temperature is too high(higher than 60 ℃)

Water flow sensor failure


Drain the pump air.
Add water to above the water level.
Drain the hot water of the water tank, and then add cold water.
Clean the water flow sensor or replace a new one
E12 Water flow less than 1.5L when turned on for the first time
Drain the pump air.
Add water to above the water level.
E03

The power tube overheating

Improve the main unit ventilation environment

E04 Overload

Appropriate increase the distance of the heating sensor from the bottle

E05

Heating sensor disengagement

Check the heating sensor connection

E06

Overcurrent or other faults

Heating sensor faults

Please refer to items 4 and 6 above

Repair the heating sensor


Air cooled induction cap sealer


Error Code Cause
Solution
E01

Input voltage is lower than 175V

Ensure that the machine is used at rated voltage(AC 220 V)

E02

The control line of the Heating sensor disengagement

Check the heating sensor connection


E03
The power tube overheating
Improve the main unit ventilation environment
E04 Overload

Appropriate increase the distance of the heating sensor from the bottle

E05

Heating sensor disengagement

Check the heating sensor connection

E06

Overcurrent or other faults

Please refer to items 4 and 6 above


Newsletternewsletter des